We have examined the plasma Factor VIII/von Willebrand factor (FVIII/vWF) molecule from 16 patients with von Willebrand's disease, and have found no evidence of a significant decrease of carbohydrate content in 15 of these patients. FVIII/vWF was isolated by preparative counter immunoelectrophoresis directly from plasma using antibody to Factor VIII-related antigen, reduced in sodium dodecyl sulfate in the presence of urea, and electrophoresed in 5% polyacrylamide gels to separate the FVIII/vWF subunit from other proteins. Duplicate gels were stained by either the periodic acid-Schiff (PAS) reaction or by Coomassie Brilliant Blue G250. The ratio of Coomassie: PAS was determined by spectrophotometric scanning of the gels. Transferrin was used as an internal reference standard. The ratio for 23 normal individuals was 2.4±0.38 and the observed range was 1.8-3.8. 15 patients with von Willebrand's disease fell within this range. One patient independently reported as having decreased FVIII/vWF carbohydrate was also studied by this technique. A ratio of 6.8 was found, indicative of decreased, though not absent, carbohydrate. Cold insoluble globulin did not represent a significant contaminant in these analyses. 11 of the von Willebrand's disease patients with normal FVIII/vWF carbohydrate had abnormal crossed immunoelectrophoretic patterns characterized by absence of the less anodic forms of Factor VIII-related antigen. Four patients had normal patterns. These studies indicate that an absence or decrease of PAS reactive FVIII/vWF carbohydrate is not a consistent abnormality in von Willebrand's disease.
T. S. Zimmerman, R. Voss, T. S. Edgington
Usage data is cumulative from May 2023 through May 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 58 | 0 |
38 | 18 | |
Scanned page | 37 | 0 |
Citation downloads | 10 | 0 |
Totals | 143 | 18 |
Total Views | 161 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.