Abstract

A constant infusion, indicator dilution technique for blood flow measurements in the forearm and hand of man was tested and validated in vitro and in vivo. This technique employs jet injection to improve mixing of indicator with arterial blood. The mixing characteristics of the jet injection system were studied in vitro in tubing simulating the brachial artery of man. In addition, actual blood flows in the isolated pump-perfused forelimbs of five dogs were compared with constant infusion, indicator dilution calculated flows. Measurements were also made of mixing and of blood flow in the forearm and hand of man. The technique was used to compare forearm and hand vascular responses with constant intrabrachial arterial infusions of magnesium sulfate in 13 normotensive and 13 essential hypertensive men.

Authors

Henry W. Overbeck, Robert M. Daugherty Jr., Francis J. Haddy

×

Other pages: