Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
  • Clinical Research and Public Health
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • ASCI Milestone Awards
    • Video Abstracts
    • Conversations with Giants in Medicine
  • Reviews
    • View all reviews ...
    • The cGAS-STING pathway: DNA sensing in health and disease (Jun 2026)
    • Neurodegeneration (Mar 2026)
    • Clinical innovation and scientific progress in GLP-1 medicine (Nov 2025)
    • Pancreatic Cancer (Jul 2025)
    • Complement Biology and Therapeutics (May 2025)
    • Evolving insights into MASLD and MASH pathogenesis and treatment (Apr 2025)
    • Microbiome in Health and Disease (Feb 2025)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Clinical Research and Public Health
    • Research Letters
    • Letters to the Editor
    • Editorials
    • Commentaries
    • Editor's notes
    • Reviews
    • Viewpoints
    • 100th anniversary
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • ASCI Milestone Awards
  • Video Abstracts
  • Conversations with Giants in Medicine
  • In-Press Preview
  • Clinical Research and Public Health
  • Research Letters
  • Letters to the Editor
  • Editorials
  • Commentaries
  • Editor's notes
  • Reviews
  • Viewpoints
  • 100th anniversary
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact

Usage Information

Quantification of Aquaporin-CHIP water channel protein in microdissected renal tubules by fluorescence-based ELISA.
Y Maeda, B L Smith, P Agre, M A Knepper
Y Maeda, B L Smith, P Agre, M A Knepper
View: Text | PDF
Research Article

Quantification of Aquaporin-CHIP water channel protein in microdissected renal tubules by fluorescence-based ELISA.

  • Text
  • PDF
Abstract

Several transporters have been localized along the nephron by physiological methods or immunocytochemistry. However, the actual abundance of these molecules has not been established. To accomplish this goal, we have developed a fluorescence-based ELISA method and have used it to quantitate Aquaporin-CHIP (AQP-CHIP) water channel protein in rat kidney tubules. Microdissected tubules (2 mm/sample, permeabilized with 0.5% Triton X-100) or purified AQP-CHIP standards (0-200 fmol) were utilized in a fluorescence ELISA protocol after covalent immobilization on epoxy-activated Sepharose beads. The lower limit of detection was 2.4 fmol of AQP-CHIP. Preabsorption with excess purified AQP-CHIP or use of nonimmune serum eliminated the signal. In proximal segments, the measured AQP-CHIP was linearly related to tubule length (1-10 mm). The measured AQP-CHIP was (mean +/- SE, fmol/mm): S-1 proximal, 10.8 +/- 2.1; S-2, 10.0 +/- 2.3; S-3, 21.3 +/- 3.1; type 1 thin descending limb (DTL), 12.9 +/- 4.6; type 2 DTL, 86.5 +/- 19.5; type 3 DTL, 43.0 +/- 11.2. In thin ascending limbs, thick ascending limbs, distal convoluted tubules, connecting tubules, and collecting ducts, the AQP-CHIP signal was indistinguishable from zero. Based on the unit water conductance of single CHIP molecules, our calculations show that the content of AQP-CHIP is sufficient to explain water permeability measured in isolated proximal tubules and DTL segments.

Authors

Y Maeda, B L Smith, P Agre, M A Knepper

×

Usage data is cumulative from June 2025 through June 2026.

Usage JCI PMC
Text version 433 21
PDF 141 2
Scanned page 554 0
Citation downloads 148 0
Totals 1,276 23
Total Views 1,299
(Click and drag on plot area to zoom in. Click legend items above to toggle)

Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.

Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.

Advertisement

Copyright © 2026 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts