The aim of this study was to examine whether altered plasma viscosity could contribute to the inappropriately low production rate of erythropoietin (EPO) observed in patients suffering from hypergammaglobulinemias associated with multiple myeloma or Waldenström's disease. We found that the EPO formation in response to anemia in these patients was inversely related to plasma viscosity. A similar inverse relationship between plasma viscosity and EPO production was seen in rats in which EPO formation had been stimulated by exchange transfusion and the plasma viscosity of which was thereby altered by using exchange solutions of different composition to alter plasma viscosity and thus whole blood viscosity independently from hematocrit. Raising the gammaglobulin concentration to approximately 40 mg/ml plasma in the rats almost totally blunted the rise in serum EPO levels despite a fall of the hematocrit to 20%. Determination of renal EPO mRNA levels by RNase protection revealed that the reductions in serum EPO levels at higher plasma viscosities were paralleled by reductions in renal EPO mRNA levels. Taken together, our findings suggest that plasma viscosity may be a significant inhibitory modulator of anemia-induced EPO formation. The increased plasma viscosity in patients with hypergammaglobulinemias may therefore contribute to the inappropriate EPO production, which is a major reason for the anemia developing in these patients.
A Singh, K U Eckardt, A Zimmermann, K H Götz, M Hamann, P J Ratcliffe, A Kurtz, W H Reinhart
Usage data is cumulative from August 2025 through August 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 415 | 15 |
| 201 | 3 | |
| Scanned page | 563 | 4 |
| Citation downloads | 196 | 0 |
| Totals | 1,375 | 22 |
| Total Views | 1,397 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.