The human Factor VIII procoagulant protein (VIII:C) purified from commercial Factor VIII concentrate consisted of a polypeptide doublet of 80,000 mol wt, a 92,000-mol wt polypeptide, and additional polypeptides of up to 188,000 mol wt. Thrombin digests contained a doublet of 72,000 mol wt, as well as 54,000- and 44,000-mol wt fragments. Proteolysis studies of purified VIII:C using thrombin and activated protein C have suggested that the 92,000- and 80,000 (or 72,000)-mol wt polypeptides comprise activated VIII:C. We have now used seven monoclonal antibodies raised against purified VIII:C to construct a preliminary epitope map of these VIII:C polypeptides. The specific VIII:C polypeptides with which the monoclonal antibodies reacted were determined by immunoblotting of VIII:C onto nitrocellulose sheets after reduced NaDodSO4-polyacrylamide gel electrophoresis. A minimum of five distinct epitopes were defined by these monoclonal anti-VIII:C antibodies. Identification of polypeptides bearing these epitopes allowed localization of distinct thrombin cleavage sites to the 92,000- and 80,000-mol wt chains, helped define polypeptide chain precursor-product relationships, and suggested that both the 92,000- and 80,000-mol wt polypeptides are necessary for VIII:C function. These data and their interpretation are consistent with the published description of the complete primary structure of VIII:C and its thrombin cleavage products. The 92,000- and 80,000-mol wt chains have been located at the amino- and carboxy-terminal ends of the molecule, respectively.
C A Fulcher, J R Roberts, L Z Holland, T S Zimmerman
Usage data is cumulative from October 2025 through October 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 299 | 8 |
| 195 | 5 | |
| Figure | 0 | 2 |
| Scanned page | 716 | 0 |
| Citation downloads | 212 | 0 |
| Totals | 1,422 | 15 |
| Total Views | 1,437 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.