Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Alerts
  • Advertising
  • Job board
  • Subscribe
  • Contact
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • Conversations with Giants in Medicine
    • Author's Takes
  • Reviews
    • View all reviews ...
    • Lung inflammatory injury and tissue repair (Jul 2023)
    • Immune Environment in Glioblastoma (Feb 2023)
    • Korsmeyer Award 25th Anniversary Collection (Jan 2023)
    • Aging (Jul 2022)
    • Next-Generation Sequencing in Medicine (Jun 2022)
    • New Therapeutic Targets in Cardiovascular Diseases (Mar 2022)
    • Immunometabolism (Jan 2022)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Commentaries
    • Research letters
    • Letters to the editor
    • Editorials
    • Viewpoint
    • Top read articles
  • Clinical Medicine
  • JCI This Month
    • Current issue
    • Past issues

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • Conversations with Giants in Medicine
  • Author's Takes
  • In-Press Preview
  • Commentaries
  • Research letters
  • Letters to the editor
  • Editorials
  • Viewpoint
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Alerts
  • Advertising
  • Job board
  • Subscribe
  • Contact
Top
  • View PDF
  • Download citation information
  • Send a comment
  • Share this article
  • Terms of use
  • Standard abbreviations
  • Need help? Email the journal
  • Top
  • Abstract
  • Version history
  • Article usage
  • Citations to this article

Advertisement

Research Article Free access | 10.1172/JCI111342

Inert gas analysis of ventilation-perfusion matching during hemodialysis.

D D Ralph, S M Ott, D J Sherrard, and M P Hlastala

Find articles by Ralph, D. in: JCI | PubMed | Google Scholar

Find articles by Ott, S. in: JCI | PubMed | Google Scholar

Find articles by Sherrard, D. in: JCI | PubMed | Google Scholar

Find articles by Hlastala, M. in: JCI | PubMed | Google Scholar

Published May 1, 1984 - More info

Published in Volume 73, Issue 5 on May 1, 1984
J Clin Invest. 1984;73(5):1385–1391. https://doi.org/10.1172/JCI111342.
© 1984 The American Society for Clinical Investigation
Published May 1, 1984 - Version history
View PDF
Abstract

The mechanism of hypoxemia during hemodialysis was investigated by the multiple inert gas elimination technique in anesthetized, paralyzed, mechanically ventilated dogs. Profound leukopenia occurred in the first hour of a 2-h hemodialysis with a cuprophan membrane and dialysate that contained acetate. Arterial partial pressure of O2 and CO2 and oxygen consumption remained unchanged during dialysis. Pulmonary carbon dioxide elimination and lung respiratory exchange ratio decreased with the initiation of dialysis, remained depressed throughout the duration of dialysis, and returned to predialysis levels after the cessation of dialysis. Cardiac output diminished during dialysis but did not return to base-line levels after dialysis. Multiple indices calculated from inert gas analysis revealed no ventilation-perfusion mismatching during dialysis. The shunt and perfusion to regions of low alveolar ventilation-to-perfusion ratio (VA/Q) were unchanged during dialysis. There was no change in the mean or standard deviation of the profile of the percentage of total perfusion to regions of the lung that had VA/Q near 1.0; nor was there any increase in the directly calculated arterial-alveolar partial pressure differences for the inert gases during dialysis. Dead space became mildly elevated during dialysis. These results show that during dialysis with controlled ventilation there is no ventilation-perfusion mismatching that leads to hypoxemia. During spontaneous ventilation any hypoxemia must occur due to hypoventilation secondary to the CO2 exchange by the dialyzer and subsequent reduction in pulmonary CO2 exchange.

Browse pages

Click on an image below to see the page. View PDF of the complete article

icon of scanned page 1385
page 1385
icon of scanned page 1386
page 1386
icon of scanned page 1387
page 1387
icon of scanned page 1388
page 1388
icon of scanned page 1389
page 1389
icon of scanned page 1390
page 1390
icon of scanned page 1391
page 1391
Version history
  • Version 1 (May 1, 1984): No description

Article tools

  • View PDF
  • Download citation information
  • Send a comment
  • Share this article
  • Terms of use
  • Standard abbreviations
  • Need help? Email the journal

Metrics

  • Article usage
  • Citations to this article

Go to

  • Top
  • Abstract
  • Version history
Advertisement
Advertisement

Copyright © 2023 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts