Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
  • Clinical Research and Public Health
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • Conversations with Giants in Medicine
    • Video Abstracts
  • Reviews
    • View all reviews ...
    • Complement Biology and Therapeutics (May 2025)
    • Evolving insights into MASLD and MASH pathogenesis and treatment (Apr 2025)
    • Microbiome in Health and Disease (Feb 2025)
    • Substance Use Disorders (Oct 2024)
    • Clonal Hematopoiesis (Oct 2024)
    • Sex Differences in Medicine (Sep 2024)
    • Vascular Malformations (Apr 2024)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Clinical Research and Public Health
    • Research Letters
    • Letters to the Editor
    • Editorials
    • Commentaries
    • Editor's notes
    • Reviews
    • Viewpoints
    • 100th anniversary
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • Conversations with Giants in Medicine
  • Video Abstracts
  • In-Press Preview
  • Clinical Research and Public Health
  • Research Letters
  • Letters to the Editor
  • Editorials
  • Commentaries
  • Editor's notes
  • Reviews
  • Viewpoints
  • 100th anniversary
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact

Usage Information

Alteration of human erythrocyte membrane properties by complement fixation.
J R Durocher, … , J P Gockerman, M E Conrad
J R Durocher, … , J P Gockerman, M E Conrad
Published April 1, 1975
Citation Information: J Clin Invest. 1975;55(4):675-680. https://doi.org/10.1172/JCI107976.
View: Text | PDF
Research Article

Alteration of human erythrocyte membrane properties by complement fixation.

  • Text
  • PDF
Abstract

Erythrocyte survival studies of complement-coated radiolabeled erythrocytes have shown rapid removal of these cells from the peripheral blood with a return of these cells into the circulation within a few hours. We studied complement-coated human erythrocytes and measured surface charge and deformability, two parameters believed to be important in erythrocyte survival. Erythrocytes were coated with complement by two in vitro techniques: the addition of (a) low ionic strength sucrose, and (b) IgM cold agglutinins. Erythrocytes obtained from three patients with cold agglutinin disease were used as a source of in vivo complement-coated cells. No difference was found in surface charge as measured by electrophoretic mobility between erythrocytes from normal subjects and complement-coated erythrocytes from any of the three sources. When deformability was measured by filtration through 3-mum polycarbonate sieves, marked decreases in deformability were found in complement-coated erythrocytes. The filtration returned toward control levels by incubating the complement-coated erythrocytes in serum for 1 h and correlated with decreases in immune adherence. Using screen filtration pressure as a measure of deformability, a positive correlation between number of C3 molecules per erythrocyte and decreased deformability was found. C3b appeared responsible for the decreased deformability of the erythrocytes, since conversion of C3b to C3d resulted in a return of deformability toward normal. The data suggested that the sequestration of complement-coated human erythrocytes in the microvasculature can be explained in part by decreased deformability and changes in immune adherence.

Authors

J R Durocher, J P Gockerman, M E Conrad

×

Usage data is cumulative from May 2024 through May 2025.

Usage JCI PMC
Text version 93 0
PDF 47 18
Scanned page 213 4
Citation downloads 61 0
Totals 414 22
Total Views 436
(Click and drag on plot area to zoom in. Click legend items above to toggle)

Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.

Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.

Advertisement

Copyright © 2025 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts