Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
  • Clinical Research and Public Health
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • Conversations with Giants in Medicine
    • Video Abstracts
  • Reviews
    • View all reviews ...
    • Complement Biology and Therapeutics (May 2025)
    • Evolving insights into MASLD and MASH pathogenesis and treatment (Apr 2025)
    • Microbiome in Health and Disease (Feb 2025)
    • Substance Use Disorders (Oct 2024)
    • Clonal Hematopoiesis (Oct 2024)
    • Sex Differences in Medicine (Sep 2024)
    • Vascular Malformations (Apr 2024)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Clinical Research and Public Health
    • Research Letters
    • Letters to the Editor
    • Editorials
    • Commentaries
    • Editor's notes
    • Reviews
    • Viewpoints
    • 100th anniversary
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • Conversations with Giants in Medicine
  • Video Abstracts
  • In-Press Preview
  • Clinical Research and Public Health
  • Research Letters
  • Letters to the Editor
  • Editorials
  • Commentaries
  • Editor's notes
  • Reviews
  • Viewpoints
  • 100th anniversary
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact

Submit a comment

Disposable platform provides visual and color-based point-of-care anemia self-testing
Erika A. Tyburski, … , L. Andrew Lyon, Wilbur A. Lam
Erika A. Tyburski, … , L. Andrew Lyon, Wilbur A. Lam
Published August 26, 2014
Citation Information: J Clin Invest. 2014;124(10):4387-4394. https://doi.org/10.1172/JCI76666.
View: Text | PDF
Clinical Research and Public Health Hematology

Disposable platform provides visual and color-based point-of-care anemia self-testing

  • Text
  • PDF
Abstract

BACKGROUND. Anemia, or low blood hemoglobin (Hgb) levels, afflicts 2 billion people worldwide. Currently, Hgb levels are typically measured from blood samples using hematology analyzers, which are housed in hospitals, clinics, or commercial laboratories and require skilled technicians to operate. A reliable, inexpensive point-of-care (POC) Hgb test would enable cost-effective anemia screening and chronically anemic patients to self-monitor their disease. We present a rapid, stand-alone, and disposable POC anemia test that, via a single drop of blood, outputs color-based visual results that correlate with Hgb levels.

METHODS. We tested blood from 238 pediatric and adult patients with anemia of varying degrees and etiologies and compared hematology analyzer Hgb levels with POC Hgb levels, which were estimated via visual interpretation using a color scale and an optional smartphone app for automated analysis.

RESULTS. POC Hgb levels correlated with hematology analyzer Hgb levels (r = 0.864 and r = 0.856 for visual interpretation and smartphone app, respectively), and both POC test methods yielded comparable sensitivity and specificity for detecting any anemia (n = 178) (<11 g/dl) (sensitivity: 90.2% and 91.1%, specificity: 83.7% and 79.2%, respectively) and severe anemia (n = 10) (<7 g/dl) (sensitivity: 90.0% and 100%, specificity: 94.6% and 93.9%, respectively).

CONCLUSIONS. These results demonstrate the feasibility of this POC color-based diagnostic test for self-screening/self-monitoring of anemia.

TRIAL REGISTRATION. Not applicable.

FUNDING. This work was funded by the FDA-funded Atlantic Pediatric Device Consortium, the Georgia Research Alliance, Children’s Healthcare of Atlanta, the Georgia Center of Innovation for Manufacturing, and the InVenture Prize and Ideas to Serve competitions at the Georgia Institute of Technology.

Authors

Erika A. Tyburski, Scott E. Gillespie, William A. Stoy, Robert G. Mannino, Alexander J. Weiss, Alexa F. Siu, Rayford H. Bulloch, Karthik Thota, Anyela Cardenas, Wilena Session, Hanna J. Khoury, Siobhán O’Connor, Silvia T. Bunting, Jeanne Boudreaux, Craig R. Forest, Manila Gaddh, Traci Leong, L. Andrew Lyon, Wilbur A. Lam

×

Guidelines

The Editorial Board will only consider comments that are deemed relevant and of interest to readers. The Journal will not post data that have not been subjected to peer review; or a comment that is essentially a reiteration of another comment.

  • Comments appear on the Journal’s website and are linked from the original article’s web page.
  • Authors are notified by email if their comments are posted.
  • The Journal reserves the right to edit comments for length and clarity.
  • No appeals will be considered.
  • Comments are not indexed in PubMed.

Specific requirements

  • Maximum length, 400 words
  • Entered as plain text or HTML
  • Author’s name and email address, to be posted with the comment
  • Declaration of all potential conflicts of interest (even if these are not ultimately posted); see the Journal’s conflict-of-interest policy
  • Comments may not include figures
This field is required
This field is required
This field is required
This field is required
This field is required
This field is required

Copyright © 2025 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts