Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
  • Clinical Research and Public Health
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • Conversations with Giants in Medicine
    • Video Abstracts
  • Reviews
    • View all reviews ...
    • Pancreatic Cancer (Jul 2025)
    • Complement Biology and Therapeutics (May 2025)
    • Evolving insights into MASLD and MASH pathogenesis and treatment (Apr 2025)
    • Microbiome in Health and Disease (Feb 2025)
    • Substance Use Disorders (Oct 2024)
    • Clonal Hematopoiesis (Oct 2024)
    • Sex Differences in Medicine (Sep 2024)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Clinical Research and Public Health
    • Research Letters
    • Letters to the Editor
    • Editorials
    • Commentaries
    • Editor's notes
    • Reviews
    • Viewpoints
    • 100th anniversary
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • Conversations with Giants in Medicine
  • Video Abstracts
  • In-Press Preview
  • Clinical Research and Public Health
  • Research Letters
  • Letters to the Editor
  • Editorials
  • Commentaries
  • Editor's notes
  • Reviews
  • Viewpoints
  • 100th anniversary
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact

Submit a comment

Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.
H L Dorkin, … , J J Fredberg, I D Frantz 3rd
H L Dorkin, … , J J Fredberg, I D Frantz 3rd
Published September 1, 1983
Citation Information: J Clin Invest. 1983;72(3):903-910. https://doi.org/10.1172/JCI111061.
View: Text | PDF
Research Article

Respiratory system impedance from 4 to 40 Hz in paralyzed intubated infants with respiratory disease.

  • Text
  • PDF
Abstract

To describe the mechanical characteristics of the respiratory system in intubated neonates with respiratory disease, we measured impedance and resistance in six paralyzed intubated infants with respiratory distress syndrome, three of whom also had pulmonary interstitial emphysema. We subtracted the effects of the endotracheal tube after showing that such subtraction was valid. Oscillatory flow was generated from 4 to 40 Hz by a loudspeaker, airway pressure was measured, and flow was calculated from pressure changes in an airtight enclosure mounted behind the flow source (speaker plethysmograph). After subtraction of the endotracheal tube contribution, resistance ranged from 22 to 34 cmH2O liter-1 s; compliance from 0.22 to 0.68 ml/cmH2O; and inertance from 0.0056 to 0.047 cmH2O liter-1 s2. Our results indicate that, for these intubated infants, the mechanics of the respiratory system are well described as resistance, compliance, and inertance in series. Most of the inertance, some of the resistance, and little of the compliance are due to the endotracheal tube. When the contribution of the endotracheal tube is subtracted, the results are descriptive of the subglottal respiratory system. These data characterize the neonatal respiratory system of infants with respiratory distress syndrome (with or without pulmonary interstitial emphysema) in the range of frequencies used during high frequency ventilation.

Authors

H L Dorkin, A R Stark, J W Werthammer, D J Strieder, J J Fredberg, I D Frantz 3rd

×

Guidelines

The Editorial Board will only consider comments that are deemed relevant and of interest to readers. The Journal will not post data that have not been subjected to peer review; or a comment that is essentially a reiteration of another comment.

  • Comments appear on the Journal’s website and are linked from the original article’s web page.
  • Authors are notified by email if their comments are posted.
  • The Journal reserves the right to edit comments for length and clarity.
  • No appeals will be considered.
  • Comments are not indexed in PubMed.

Specific requirements

  • Maximum length, 400 words
  • Entered as plain text or HTML
  • Author’s name and email address, to be posted with the comment
  • Declaration of all potential conflicts of interest (even if these are not ultimately posted); see the Journal’s conflict-of-interest policy
  • Comments may not include figures
This field is required
This field is required
This field is required
This field is required
This field is required
This field is required

Copyright © 2025 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts