Platelet adhesion and thrombus formation on subendothelium, studied at a shear rate of 2,600 s-1, were inhibited by two synthetic peptides known to interact with GPIIb-IIIa. One peptide (HHLGGAKQAGDV) corresponds to the carboxyl terminal segment of the fibrinogen gamma-chain (gamma 400-411) and the other (RGDS) contains the amino acid sequence Arg-Gly-Asp (RGD) common to fibronectin, von Willebrand factor, vitronectin and the alpha-chain of fibrinogen. Neither platelet adhesion nor thrombus formation were decreased in a patient with severe congenital fibrinogen deficiency and this was equally true when his blood was further depleted of the small amounts of fibrinogen present utilizing an anti-fibrinogen antibody. In normal subjects, adhesion and thrombus formation were inhibited by the Fab' fragments of a monoclonal anti-GPIIb-IIIa antibody (LJ-CP8), which interferes with the interaction of platelets with all four adhesive proteins in both the fluid and solid phase. However, another anti-GPIIb-IIIa antibody (LJ-P5) that had minimal effects on the interaction of platelets with fibrinogen, but inhibited to varying degrees platelet interaction with other adhesive proteins, was equally effective. The findings demonstrate that, at a shear rate of 2,600 s-1, adhesive proteins other than fibrinogen are involved in GPIIb-IIIa-mediated platelet adhesion and thrombus formation on subendothelium. In addition, since LJ-P5 inhibited the binding of soluble von Willebrand factor and vitronectin, these adhesive proteins may be involved in platelet thrombus formation. In contrast to the results obtained at a shear rate of 2,600 s-1, fibrinogen could play a role in mediating platelet-platelet interactions with weak agonists or lower shear rates.
H J Weiss, J Hawiger, Z M Ruggeri, V T Turitto, P Thiagarajan, T Hoffmann
Usage data is cumulative from February 2025 through February 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 618 | 17 |
| 82 | 17 | |
| Scanned page | 520 | 1 |
| Citation downloads | 95 | 0 |
| Totals | 1,315 | 35 |
| Total Views | 1,350 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.