To examine whether Cl- is transported via transcellular pathways in the thin ascending limb of Henle's loop (TAL), conventional microelectrode technique was applied in isolated TAL segments of hamsters perfused in vitro. The average basolateral membrane voltage (VB) was -24.5 +/- 1.5 mV (n = 18). Ouabain (10(-4) M) had no effect on VB. Sudden reduction of basolateral Cl- concentration from 165 to 5 mmol/liter caused a large depolarizing spike (+49.1 +/- 2.7 mV, n = 18), while the transepithelial potential (VT) showed lumen positive deflection by 33.4 +/- 1.2 mV, which indicates that a large Cl- conductance exists in the basolateral membrane. Reduction of luminal Cl- concentration caused sustained depolarization of luminal cell membrane from +24.5 +/- 2.1 to -9.7 +/- 3.4 mV (n = 6), which indicates that there is also a Cl- conductance in the luminal membrane. Since we have previously shown that acidification of ambient solution suppresses the transmural Cl- permeability, we tested whether acid pH also inhibits the Cl- conductance of the basolateral membrane. When pH of the bathing fluid was lowered to 5.8, the depolarizing spike of VB and the change of VT upon sudden reduction of basolateral Cl- were almost completely abolished. From these results we conclude: (a) both the luminal and the basolateral membrane of hamster TAL segments have Cl- conductances, and (b) Cl- transport in the TAL takes place, at least in part, via a transcellular route when a transepithelial Cl- gradient is present.
K Yoshitomi, Y Kondo, M Imai
Usage data is cumulative from November 2024 through November 2025.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 106 | 2 |
| 45 | 1 | |
| Scanned page | 113 | 0 |
| Citation downloads | 43 | 0 |
| Totals | 307 | 3 |
| Total Views | 310 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.