The major pathway for HCO3- transport across the basolateral membrane of the proximal tubule cell is electrogenic Na+-HCO3- cotransport. In this study, we have determined the stoichiometry of the Na+-HCO3- cotransport system in basolateral membrane vesicles that were isolated from rabbit renal cortex by Percoll gradient centrifugation. When the membrane potential is approximated by the Nernst potential for K+, as in the presence of the K+ ionophore valinomycin, equilibrium thermodynamics predicts that the Na+-HCO3- cotransport system should come to equilibrium and mediate no net flux when (Na)i/(Na)o = [(HCO3)o/(HCO3)i]n[(K)o/(K)i]n-1, where n is the HCO3-:Na+ stoichiometry. Our experimental approach was to impose transmembrane Na+, HCO3-, and K+ gradients of varying magnitude and direction, and then to measure the net flux of Na+ over the subsequent 3-s period. In this way, we could determine the conditions for equilibrium of the transport system and thereby calculate n. The results of these experiments indicate that the value of n is greater than 2.6 and less than 3.5, consistent with a stoichiometry of 3 HCO3-:1 Na+, or a thermodynamically equivalent process. Based on reported intracellular potentials and ion activities, this value for the stoichiometry indicates that the inside-negative membrane potential is sufficient to drive HCO3- exit against the inward concentration gradients of HCO3- and Na+ that are present across the basolateral membrane of the intact proximal tubule cell under physiologic conditions.
M Soleimani, S M Grassi, P S Aronson
Usage data is cumulative from June 2024 through June 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 147 | 7 |
43 | 15 | |
Scanned page | 179 | 5 |
Citation downloads | 56 | 0 |
Totals | 425 | 27 |
Total Views | 452 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.