Marrow blasts from children with B cell precursor acute lymphoblastic leukemia (ALL) were studied for differences in quantitative expression of the common ALL antigen (CALLA). Of 42 untreated patients, 35 had detectable amounts of CALLA by flow cytometric (FCM) analysis of J-5 monoclonal antibody binding. Using an FCM technique that provides correlated measurements of a given cell surface antigen, cell size, and DNA content, we detected increased CALLA expression as lymphoblasts moved from G0/G1 phase through S phase of the cell cycle. The density of the antigen (per unit of blast surface area) remained relatively constant over the same interval, indicating that the change was not due to S phase-specific enhancement of CALLA expression. Eight cases had hyperdiploid cellular DNA content and in seven of these, only cells with clonal abnormalities of DNA content expressed the CALLA marker. Mean amounts of CALLA for each patient ranged widely within the study group, from very high to marginally detectable. This variation had no discernible relation to cell size, stem-line DNA content, percentage of cells in S phase, or the presence or absence of cytoplasmic immunoglobulin. Results of a univariate proportional hazards analysis showed that both quantitative level of CALLA for S phase cells (P = 0.048) and white blood cell count (P = 0.012) had made significant contributions to treatment outcome. Patients with relative amounts of CALLA less than the median value for the entire CALLA+ group had a higher rate of failure, which was virtually identical to that for the seven HLA-DR+ patients whose blasts lacked detectable CALLA. The observed interpatient variation in quantitative expression of CALLA is consistent with recognized steps in B cell precursor differentiation and may be useful in distinguishing patients with a less favorable prognosis.
A T Look, S L Melvin, L K Brown, M E Dockter, P K Roberson, S B Murphy
Usage data is cumulative from August 2024 through August 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 140 | 5 |
50 | 12 | |
Scanned page | 477 | 2 |
Citation downloads | 61 | 0 |
Totals | 728 | 19 |
Total Views | 747 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.