Human activated protein C (APC) is a plasma serine protease that possesses amidolytic and anticoagulant activity. The rate at which the amidolytic and anticoagulant activity of APC was neutralized in normal plasma was essentially identical to that observed in plasma obtained from four individuals with combined Factor V/VIII deficiency disease. Incubation of radioiodinated APC with either normal human plasma or the combined Factor V/VIII-deficient plasmas resulted in the formation of a stable complex (Mr = 96,000) of the enzyme and a plasma protein as determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Pretreatment of the radiolabeled APC with diisopropyl fluorophosphate prevented the formation of the enzyme-protein complex. On the basis of its ability to form a complex with radiolabeled APC, the APC-binding protein was purified to homogeneity from normal human plasma by ammonium sulfate fractionation, heparin-agarose chromatography, and QAE-Sephadex A-50 chromatography. The APC-binding protein (Mr = 54,000) is a glycoprotein, and possesses an amino-terminal sequence of Gly-Arg-Thr-Cys-Pro-Lys-Pro-Asp. The amino-terminal sequence of the APC-binding protein exhibited considerable homology with bovine colostrum inhibitor and pancreatic trypsin inhibitor, but no apparent sequence homology with the plasma serine protease inhibitors. Affinity-purified antibody against APC-binding protein immunoprecipitated a complex of radiolabeled APC and native APC-binding protein from normal human plasma. Complex formation was virtually eliminated in plasma immunodepleted of the APC-binding protein. Quantitative electroimmunoassay indicated essentially equal levels of APC-binding protein antigen in normal plasma compared with plasma from four patients with combined Factor V/VIII deficiency disease.
W M Canfield, W Kisiel
Usage data is cumulative from July 2024 through July 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 136 | 7 |
50 | 11 | |
Figure | 0 | 2 |
Scanned page | 467 | 4 |
Citation downloads | 47 | 0 |
Totals | 700 | 24 |
Total Views | 724 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.