The purpose of the present study was to define myocardial and blood thallium-201 (Tl-201) kinetics after infusion of dipyridamole in normal canine myocardium and in myocardium distal to a coronary artery stenosis. Miniature radiation detector probes were implanted in the left ventricle in 39 open-chest dogs. A balloon constrictor was placed around the proximal left circumflex coronary artery. Electromagnetic flow probes were positioned proximally around both the left circumflex and left anterior descending coronary arteries. In five control dogs (group 1) the balloon occluder was not inflated; in 12 dogs (group 2) a mild stenosis was created such that resting flow was not reduced, yet the hyperemic response after 10 s of total occlusion was partially attenuated; in nine dogs (group 3) a moderate stenosis was created such that resting flow was not reduced, yet the hyperemic response was completely eliminated; and in 13 dogs (group 4) a severe stenosis was created such that resting flow was reduced. After intravenous dipyridamole (0.08 mg/kg . min-1 x 4 min), 1.5 mCi Tl-201 was injected intravenously and probe counts were collected continuously for 4 h. The mean 4-h fractional myocardial Tl-201 clearance for nonstenotic zones was 0.35, 0.27 for group 2 stenotic zones, 0.19 for group 3 stenotic zones, and 0.05 for group 4 stenotic zones (P less than 0.0001). After reaching peak activity, myocardial Tl-201 activity cleared biexponentially with a final decay constant lambda 2 = 0.0017 +/- 0.0001 min-1 (SE) for nonstenotic zones, 0.0011 +/- 0.0001 min-1 for group 2 stenotic zones, and 0.0006 +/- 0.0001 min-1 for group 3 stenotic zones (P less than 0.01). Group 4 stenotic zone Tl-201 clearances were negligible (decay constant essentially zero). Blood Tl-201 activity decayed triexponentially with a final blood lambda 3 = 0.0018 +/- 0.0001 min-1, which was almost identical to the final myocardial lambda 2 decay constant. Thus, the rate of myocardial Tl-201 clearance can distinguish between coronary stenoses of graded hemodynamic severity. These results may be applicable to quantitative techniques for determining myocardial Tl-201 clearance rates on serial clinical images after dipyridamole administration.
R D Okada, J A Leppo, C A Boucher, G M Pohost
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 95 | 0 |
55 | 9 | |
Scanned page | 379 | 7 |
Citation downloads | 50 | 0 |
Totals | 579 | 16 |
Total Views | 595 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.