Go to JCI Insight
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact
  • Clinical Research and Public Health
  • Current issue
  • Past issues
  • By specialty
    • COVID-19
    • Cardiology
    • Gastroenterology
    • Immunology
    • Metabolism
    • Nephrology
    • Neuroscience
    • Oncology
    • Pulmonology
    • Vascular biology
    • All ...
  • Videos
    • Conversations with Giants in Medicine
    • Video Abstracts
  • Reviews
    • View all reviews ...
    • Complement Biology and Therapeutics (May 2025)
    • Evolving insights into MASLD and MASH pathogenesis and treatment (Apr 2025)
    • Microbiome in Health and Disease (Feb 2025)
    • Substance Use Disorders (Oct 2024)
    • Clonal Hematopoiesis (Oct 2024)
    • Sex Differences in Medicine (Sep 2024)
    • Vascular Malformations (Apr 2024)
    • View all review series ...
  • Viewpoint
  • Collections
    • In-Press Preview
    • Clinical Research and Public Health
    • Research Letters
    • Letters to the Editor
    • Editorials
    • Commentaries
    • Editor's notes
    • Reviews
    • Viewpoints
    • 100th anniversary
    • Top read articles

  • Current issue
  • Past issues
  • Specialties
  • Reviews
  • Review series
  • Conversations with Giants in Medicine
  • Video Abstracts
  • In-Press Preview
  • Clinical Research and Public Health
  • Research Letters
  • Letters to the Editor
  • Editorials
  • Commentaries
  • Editor's notes
  • Reviews
  • Viewpoints
  • 100th anniversary
  • Top read articles
  • About
  • Editors
  • Consulting Editors
  • For authors
  • Publication ethics
  • Publication alerts by email
  • Advertising
  • Job board
  • Contact

Usage Information

Mechanisms of methylene blue stimulation of the hexose monophosphate shunt in erythrocytes.
E N Metz, … , P Balcerzak, A L Sagone Jr
E N Metz, … , P Balcerzak, A L Sagone Jr
Published October 1, 1976
Citation Information: J Clin Invest. 1976;58(4):797-802. https://doi.org/10.1172/JCI108531.
View: Text | PDF
Research Article

Mechanisms of methylene blue stimulation of the hexose monophosphate shunt in erythrocytes.

  • Text
  • PDF
Abstract

The response of the hexose monophosphate shunt in erythrocytes was studied with the ionization chamber-electrometer apparatus to measure continuously 14CO2 derived from 14C-labeled substrates. The effect of methylene blue at high (0.1 mM) and low (1 muM) concentrations was evaluated under different gas mixtures; air, carbon monoxide, and 6% carbon monoxide in air. The latter gas mixture results in nearly 100% carboxyhemoglobin but provides a physiologic partial pressure of oxygen. The extent to which pentose is recycled through the shunt in response to methylene blue stimulation was examined with radioactive glucose substrates labeled on the first, second, and third carbon positions. Generation of hydrogen peroxide after stimulation of erythrocytes with methylene blue was evaluated by the catalase-aminotriazole trapping technique, [14C]formate oxidation, and oxidation of reduced glutatione. Stimulation of the shunt with 1 muM methylene blue was markedly impaired in the absence of oxyhemoglobin, but stimulation with 0.1 mM methylene blue was only slightly impaired under the carbon monoxide-air mixture. The higher concentration of methylene blue produced evidence of hydrogen peroxide generation of all three techniques. Despite the evidence for the involvement of oxygen, oxyhemoglobin, and hydrogen peroxide in the response to methylene blue, cells containing methemoglobin induced by sodium nitrite or from a patient with congenital methemoglobinemia responded normally to methylene blue in the absence of oxygen. These experiments indicate that the reactions induced by methylene blue in erythrocytes are more complex than generally thought and that high concentrations are associated with production of peroxide.

Authors

E N Metz, P Balcerzak, A L Sagone Jr

×

Usage data is cumulative from May 2024 through May 2025.

Usage JCI PMC
Text version 109 6
PDF 41 22
Scanned page 197 2
Citation downloads 67 0
Totals 414 30
Total Views 444
(Click and drag on plot area to zoom in. Click legend items above to toggle)

Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.

Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.

Advertisement

Copyright © 2025 American Society for Clinical Investigation
ISSN: 0021-9738 (print), 1558-8238 (online)

Sign up for email alerts