High levels of a novel vitamin B12-binding protein (hepatoma B12 BP) have been observed recently in plasma obtained from three adolescent patients with hepatocellular carcinoma. This protein has now been isolated in homogeneous form from the plasma and pleural fluid of two of these patients by the use of affinity chromatography with vitamin B12-Sepharose. The hepatoma B12 BP belongs to the R-type group of B12-binding proteins and is essentially indistinguishable from the recently isolated human milk and saliva R-type proteins in terms of: (a) immunologic properties based on immunodiffusion and immunoprecipitation assays; (b) amino acid composition; (c) molecular weight based on amino acid and carbohydrate content; and (d) absorption spectra. Both hepatoma B12 BPs contain more sialic acid and less fucose than the milk and saliva B12 BPs. All four proteins contain similar amounts of galactose, mannose, galactosamine, and glucosamine. Differences in sialic acid content appear to account for the differences in electrophoretic mobility that were observed among the four proteins. Differences in total carbohydrate content appear to account for the differences in apparent molecular weight that were observed with both gel filtration and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Tumor tissue from one of the patients contained 10 times as much R-type protein as did normal liver tissue from the same patient. This suggests, although it does not prove, that synthesis by the tumor is the cause of the high levels of R-type protein found in the plasma of certain patients with hepatocellular carcinoma. Plasma survival studies performed with rabbits indicate that the hepatoma B12 BP has a prolonged plasma survival and suggests that his parameter is also of importance.
R L Burger, S Waxman, H S Gilbert, C S Mehlman, R H Allen
Usage data is cumulative from June 2024 through June 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 118 | 4 |
59 | 16 | |
Scanned page | 277 | 5 |
Citation downloads | 49 | 0 |
Totals | 503 | 25 |
Total Views | 528 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.