Human factor VIII from normals and hemophiliacs was partially purified by ethanol and polyethylene glycol precipitations. Final purification was achieved by gel filtration on 2 or 4% agarose or ion exchange chromatography on diethylaminoethyl cellulose. Comparable amounts of highly purified protein were obtained from normal and hemophilic plasma following the agarose chromatography step. Highly purified factor VIII was not dissociated by 6 M guanidine hydrochloride or 1% sodium dodecyl sulfate. However, when reduced by β-mercaptoethanol and analyzed by sodium dodecyl sulfate polyacrylamide gel electrophoresis, a single subunit species with an estimated 195,000 molecular weight was found for both normal and hemophilic factor VIII. By sedimentation equilibrium analysis, the normal factor VIII subunit was homogeneous and had an estimated molecular weight of 202,000. The subunit polypeptides from normal or hemophilic factor VIII contained carbohydrate. Each was homogeneous by isoelectric focusing. Immunodiffusion of purified normal and hemophilic factor VIII against rabbit antiserum to purified normal human factor VIII showed a single line of precipitation. Very low concentrations of purified human thrombin initially increased the activity of normal factor VIII about threefold and then progressively destroyed activity by 3 h. Only minimal activation occurred with hemophilic factor VIII. Both the activation and inactivation of normal and hemophilic factor VIII were unaccompanied by detectable changes in subunit molecular weight. These findings may have implications for the definition of the molecular defect in hemophilic factor VIII.
Gabriel A. Shapiro, Judith C. Andersen, Salvatore V. Pizzo, Patrick A. McKee
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 122 | 4 |
55 | 18 | |
Scanned page | 422 | 4 |
Citation downloads | 52 | 0 |
Totals | 651 | 26 |
Total Views | 677 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.