The effects of both intracoronary and intravenous administration of nitroglycerin on transmural distribution of blood flow in the left ventricle after partial coronary artery occlusion was investigated using two independent methods. In 16 open chest, anesthetized dogs, tubing supplying the cannulated left coronary artery was partially occluded. Strain gauges sutured paralled to superficial and deep fibers of the myocardium separately recorded the contractile force of each layer. With occlusion set so that depression of the deep contractile force was imminent. 12 μg intracoronary nitroglycerin in seven dogs depressed only the deep contractile force without changing systemic hemodynamics. Intravenous administration of 180 μg nitroglycerin in nine dogs resulted in a decrease of deep contractile force and aortic pressure often associated with an increase in superficial contractile force. Distribution of myocardial blood flow during peak coronary flow after intracoronary administration of nitroglycerin or during a decrease in aortic pressure after intravenous nitroglycerin administration was determined by the tissue uptake of an intracoronary bolus of rubidium-80. This was compared with the uptake of potassium-42 injected before nitroglycerin. Intravenous or intracoronary administration of nitroglycerin caused a significant reduction in subendocardial blood flow with a decrease in the subendocardial/subepicardial ratio of isotope.
Robert Forman, Edward S. Kirk, James M. Downey, Edmund H. Sonnenblick
Usage data is cumulative from June 2024 through June 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 101 | 4 |
42 | 11 | |
Scanned page | 230 | 3 |
Citation downloads | 42 | 0 |
Totals | 415 | 18 |
Total Views | 433 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.