The effects of ouabain (G-strophanthin) 20 μg/kg, on left ventricular (LV) pressure (P), diameter (D), velocity of contraction (dD/dt), and dP/dt were studied in conscious dogs instrumented with ultrasonic diameter gauges and miniature pressure gauges. The effects of ouabain were compared on separate occasions in the same dogs after cardiac depression with propranolol, 3.0 mg/kg, and also after general anesthesia with Na pentobarbital, 30 mg/kg. Maximal pressor effects were observed in the first 10 min, but maximal effects on the contractile state occurred at 30 min after ouabain. At this time, in conscious dogs, ouabain had increased LV isolength systolic pressure by 5%, LV isolength velocity by only 9%, and LV (dP/dt)/P by 21%, while end systolic diameter (ESD) decreased slightly and end diastolic diameter (EDD) and heart rate (HR) were unchanged. After anesthesia, ouabain increased LV systolic pressure by 8%, velocity 32%, (dP/dt)/P by 47%, and ESD decreased by 1.2 mm while EDD rose slightly and HR fell by 26 beats/min. Returning HR to control with atrial pacing decreased EDD 0.9 mm below control. After cardiac depression with propranolol, ouabain caused responses similar to those observed in the anesthetized dogs. Thus, the cardiac glycoside was found to exert only minor inotropic effects on the nonfailing heart of conscious dogs but far more striking inotropic responses in the anesthetized state.
Stephen F. Vatner, Charles B. Higgins, Thomas Patrick, Dean Franklin, Eugene Braunwald
Usage data is cumulative from August 2024 through August 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 134 | 5 |
53 | 11 | |
Scanned page | 468 | 1 |
Citation downloads | 75 | 0 |
Totals | 730 | 17 |
Total Views | 747 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.