A patient who had received multiple transfusions for complications of acute hemorrhagic pancreatitis developed a potent factor V anticoagulant with bleeding due to defective hemostasis. Despite its potency, the anticoagulant disappeared within 15 days of its first manifestation. A second patient with adenocarcinoma of the colon developed an anticoagulant to factor V postoperatively after a single blood transfusion. The anticoagulants appeared to react stoichiometrically with factor V in normal plasma in vitro. They had the physicochemical properties of immunoglobulins, and their activity was neutralized by antihuman immunoglobulin antiserum. One anticoagulant appeared to be slightly more active against homologous than against autologous factor V, but it also inhibited heterologous factor V. Both anticoagulants progressively inactivated intrinsic prothrombin activator formed from normal reagents in the incubation mixture of the thromboplastin generation test, thus confirming that factor V is required for the effective action of the intrinsic prothrombin activator. Since the anticoagulants were immunoglobulins whose activity was consumed in their reaction with factor V, consumption of anticoagulant activity was used to detect factor V antigenic material in test materials. Human serum without factor V clotting activity was found to consume anticoagulant activity, i.e., to contain inactive factor V antigenic material. Plasma from two patients with hereditary factor V deficiency (parahemophilia) failed to consume significant anticoagulant activity. Thus, the lack of factor V activity in these patients represents a deficiency of factor V molecules rather than the synthesis of a defective molecule with impaired clotting activity.
Donald I. Feinstein, Samuel I. Rapaport, William G. McGehee, Mary Jane Patch
Usage data is cumulative from May 2024 through May 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 90 | 3 |
45 | 26 | |
Scanned page | 461 | 1 |
Citation downloads | 48 | 0 |
Totals | 644 | 30 |
Total Views | 674 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.