Mitochondria from rabbit and dog renal cortex were incubated with 1 mM 14C-weak acid anions in media containing low (10 mM) or high (40 mM) concentrations of bicarbonate and the steady-state accumulation of labeled anion in the matrix was measured. In the absence of an energy source, no concentration of 14C-anion in the mitochondrial matrix space was present, but the anion concentration was significantly higher at low- than at high-bicarbonate concentration. Addition of an energy source, usually ascorbate plus tetramethyl-p-phenylenediamine, led to increases in matrix space anion levels and to accentuation of the difference in anion uptake between low- and high-bicarbonate media, so that two to four times as much anion was present at low- than at high-bicarbonate concentrations. The anions affected included substrates for which inner membrane carriers are present in mitochondria, such as citrate, α-ketoglutarate, malate, and glutamate, as well as substances which diffuse passively across the inner membrane such as acetate and formate. When a nonbicarbonate medium buffered with Hepes was used, pH change did not alter anion uptake although anion concentrations exceeding those in the medium still developed when an energy source was present. The difference in mitochondrial anion accumulation between low- and high-bicarbonate levels diminished with decreasing temperature or with increasing anion concentration in the medium. Estimation of intramitochondrial pH with [14C]5,5-dimethyl-oxazolidine-2,4-dione showed that the pH gradient across the inner mitochondrial membrane was significantly greater with 10 than with 40 mM bicarbonate in the medium.
David P. Simpson, Steven R. Hager
Usage data is cumulative from January 2025 through January 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 218 | 17 |
| 80 | 5 | |
| Scanned page | 342 | 5 |
| Citation downloads | 82 | 0 |
| Totals | 722 | 27 |
| Total Views | 749 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.