The metabolic clearance rate (MCR) and renal clearance rate (RCR) of human chorionic gonadotropin (hCG) were measured in healthy young men and women using techniques of continuous intravenous infusion and rapid intravenous injection of unlabeled, highly purified hCG. Seven subjects received 4 d of infusion at a rate of 0.2 microgram/min, followed by an additional 4 d of infusion at 0.8 microgram/min. Mean serum levels of hCG established at these rates of infusion were 61.1 +/- 3.3 and 237 +/- 16 ng/ml, respectively (mean +/- SEM). The MCR determined at the low infusion rate was not significantly different from that determined at the higher infusion rate (1.83 +/- 0.09 vs. 1.95 +/- 0.14 ml/min per m2). The mean MCR for all subjects was 1.88 +/- 0.08 ml/min per m2. The MCR was not significantly different between men amd women (2.04 +/- 0.13 vs. 1.76 +/- 0.07 ml/min per m2). The RCR also did not vary between low and high infusion rates (0.40 +/- 0.03 vs. 0.40 +/- 0.04 ml/min per m2). The mean RCR for all subjects was 0.40 +/- 0.02 ml/min per m2. There was no difference in RCR between men and women (0.42 +/- 0.05 vs. 0.39 +/- 0.03 ml/min per m2). Six subjects were given 1.0 mg of highly purified hCG by rapid intravenous injection. Initial serum levels of hCG were 300-400 ng/ml, and the subsequent disappearance curve was multiexponential over 8-10 d. The disappearance curve of hCG in each subject was fitted to a biexponential equation. The rapid component t1/2 was 5.97 +/- 0.63 h and the slow component t1/2 was 35.6 +/- 8.0 h. We conclude that the MCR of purified hCG in man is about 2 ml/min per m2 and the RCR is 0.4 ml/min per m2; these parameters are concentration independent and do not differ significantly between healthy young men and women.
R E Wehmann, B C Nisula
Usage data is cumulative from April 2023 through April 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 116 | 0 |
44 | 36 | |
Scanned page | 149 | 40 |
Citation downloads | 7 | 0 |
Totals | 316 | 76 |
Total Views | 392 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.