Comparisons of Community-Associated Methicillin-Resistant Staphylococcus aureus (MRSA) and Hospital-Associated MSRA Infections in Sacramento, California

H Huang, NM Flynn, JH King… - Journal of clinical …, 2006 - Am Soc Microbiol
H Huang, NM Flynn, JH King, C Monchaud, M Morita, SH Cohen
Journal of clinical microbiology, 2006Am Soc Microbiol
Methicillin-resistant Staphylococcus aureus (MRSA) has long been a common pathogen in
healthcare facilities, but in the past decade, it has emerged as a problematic pathogen in the
community setting as well. A retrospective case series study of patients from whom MRSA
was isolated from December 1, 2003, through May 31, 2004, was conducted at the
University of California, Davis, Medical Center. Patient data were collected from electronic
medical records and traditional chart reviews to determine whether MRSA acquisition was …
Abstract
Methicillin-resistant Staphylococcus aureus (MRSA) has long been a common pathogen in healthcare facilities, but in the past decade, it has emerged as a problematic pathogen in the community setting as well. A retrospective case series study of patients from whom MRSA was isolated from December 1, 2003, through May 31, 2004, was conducted at the University of California, Davis, Medical Center. Patient data were collected from electronic medical records and traditional chart reviews to determine whether MRSA acquisition was likely to have been in the community or in the hospital. Antimicrobial susceptibility testing and pulsed-field gel electrophoresis (PFGE) were performed for all confirmed isolates. Skin and soft tissue were the most common infection sites for all MRSA patients. Among the 283 MRSA infections, 127 (44.9%) were defined as community-associated (CA)-MRSA. Ninety-six percent of the CA-MRSA isolates were susceptible to clindamycin. Double-disk diffusion tests were performed to examine inducible clindamycin resistance by erythromycin induction on both CA and hospital-associated (HA) clindamycin-susceptible and erythromycin-resistant isolates. Ten percent (17 of 183) were positive. Most CA-MRSA isolates were identified by PFGE as a unique strain, genotype USA300, which was not genetically related to the predominant genotype, USA100, in the HA-MRSA isolates. Injecting drug users accounted for 49% of CA-MRSA infections but only 19% of the HA-MRSA infections (odds ratio, 4.2; 95% confidence interval, 2.4 to 7.4). Our study shows that a single clone of CA-MRSA accounts for the majority of infections. This strain originated in the community and is not related to MRSA strains from healthcare settings. Injecting drug users could be a major reservoir for CA-MRSA transmission.
American Society for Microbiology