Monophasic action potential recordings from intact mouse heart: validation, regional heterogeneity, and relation to refractoriness

BC Knollmann, AN Katchman… - Journal of …, 2001 - Wiley Online Library
BC Knollmann, AN Katchman, MR Franz
Journal of cardiovascular electrophysiology, 2001Wiley Online Library
MAP Recordings from Mouse Heart. Introduction: The monophasic action potential (MAP)
technique has been validated in humans and larger animals, but, in mice, MAP recordings
available to date show little resemblance to the murine ventricular transmembrane action
potential (TAP) measured by conventional microelectrodes. We developed a miniaturized
MAP contact electrode technique to establish in isolated mouse hearts:(1) optimal electrode
size;(2) validation against TAP;(3) relationship between repolarization and refractoriness; …
MAP Recordings from Mouse Heart. Introduction: The monophasic action potential (MAP) technique has been validated in humans and larger animals, but, in mice, MAP recordings available to date show little resemblance to the murine ventricular transmembrane action potential (TAP) measured by conventional microelectrodes. We developed a miniaturized MAP contact electrode technique to establish in isolated mouse hearts: (1) optimal electrode size; (2) validation against TAP; (3) relationship between repolarization and refractoriness; and (4) regional repolarization differences.
Methods and Results: In 30 Langendorff‐perfused mouse hearts, MAP electrodes of tip diameter 1.5, 1.0, and 0.25 mm were tested by comparing MAPs and TAPs from epicardial and endocardial surfaces of both ventricles. Only the MAP contact electrode of 0.25‐mm tip diameter consistently produced MAP recordings that had wave shapes nearly identical to TAP recordings. MAP durations measured at 30%, 50%, 70%, and 90% repolarization (APD30, APD50, APD70, APD90) highly correlated with TAP measurements (r = 0.97, P < 0.00001). APD50 was significantly longer in endocardial than in epicardial recordings (right ventricle: 9.3 ± 1.1 msec vs 3.9 ± 1.1 msec; left 
ventricle: 9.9 ± 2.1 msec vs 6.2 ± 1.9 msec; both P < 0.001), demonstrating transmural repolarization differences. Effective refractory period (ERP) determined at basic cycle lengths from 70 to 200 msec correlated with 80% ± 6% of total repolarization, with an ERP/APD90 ratio of 0.85 ± 0.14.
Conclusion: Murine myocardial repolarization, regional repolarization heterogeneity, and relation to refractoriness can be assessed reliably by this miniaturized MAP contact electrode technique, which renders action potential wave shapes similar to that of intracellular microelectrodes. This technique may be useful for exploring repolarization abnormalities in genetically altered mice.
Wiley Online Library