Occlusive thrombus was produced by thrombin-induced coagulation in the left anterior descending coronary artery (LAD) of 16 open-chest baboons. In six control animals, occlusive thrombosis persisting over a period of 4 h as evidenced by coronary arteriography resulted in large transmural infarction (63.1 +/- 3.5% of the perfusion area). In 10 animals, tissue-type plasminogen activator obtained by recombinant DNA technology (rt-PA) was infused systemically at a rate of 1,000 IU (10 micrograms)/kg per min for 30 min after 30-80 min of coronary thrombosis. Reperfusion occurred within 30 min in nine animals. In one animal, intravenous infusion was followed by an intracoronary infusion at the same rate, which resulted in thrombolysis within 8 min. In the rt-PA group, mean duration of occlusion before reperfusion was 77 +/- 24 min. Reocclusion occurred in one animal. Recanalization resulted in an overall reduction of infarct size (37.8 +/- 5.9%, P less than 0.05 versus controls). Residual infarction was related to the duration of occlusion (r = 0.80, P less than 0.01). Reperfusion was associated with reduced reflow. Myocardial blood flow in the perfusion area of the LAD was only 70% of normal after 4 h despite perfect angiographic refilling. The infusion of rt-PA was not associated with systemic activation of the fibrinolytic system, fibrinogen breakdown, or clinically evident bleeding. It is concluded that intravenous infusion of rt-PA may recanalize thrombosed coronary vessels without inducing systemic lysis. The extent of residual infarction is closely related to the duration of coronary artery occlusion before thrombolysis.
W Flameng, F Van de Werf, J Vanhaecke, M Verstraete, D Collen
Usage data is cumulative from May 2025 through May 2026.
| Usage | JCI | PMC |
|---|---|---|
| Text version | 217 | 4 |
| 105 | 12 | |
| Scanned page | 541 | 1 |
| Citation downloads | 131 | 0 |
| Totals | 994 | 17 |
| Total Views | 1,011 | |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.