A cytochemical bioassay for parathyroid hormone (PTH) was used for the characterization of the biological activity of circulating forms of the hormone. PTH-stimulated glucose-6-phosphate dehydrogenase activity in distal convoluted tubule cells was quantitated by integrating microdensitometry and the response to native bovine (b)PTH(1-84) was found to be linear between graded doses of hormone from 5 fg/ml to 5 pg/ml. Synthetic bPTH(1-34) and human (h)PTH(1-34) elicited a parallel and equimolar response; however calcitonin, ACTH, glucagon, epinephrine, vasopressin, and insulin failed to significantly stimulate the enzyme in doses up to 100,000 times greater than the lowest concentration of bPTH used. The assay was capable of distinguishing hormonal activity in normal, hypoparathyroid, and hyperparathyroid human plasma. After gel chromatography, bioactivity in plasma of hyperparathyroid patients with skeletal disease but normal kidney function coeluted mainly with bPTH(1-84), whereas bioactivity in plasma of hyperparathyroid patients with skeletal disease but severe uremia coeluted in approximately equivalent amounts with bPTH(1-84) and hPTH(1-34). Despite the abundance of small molecular-weight bioactivity in the peripheral circulation in uremia, ∼85% of the bioactivity in the parathyroid venous effluent coeluted with bPTH(1-84). The results therefore demonstrate the sensitivity and specificity of the assay for PTH and its utility in measuring the hormone in human parathyroid disorders. The results furthermore demonstrate the importance of entities cochromatographing with bPTH(1-84) in comprising the circulating bioactive hormone in hyperparathyroidism, and support the concept of a biological role for smaller forms of PTH, at least in chronic renal failure.
David Goltzman, Brian Henderson, Nigel Loveridge
Usage data is cumulative from February 2022 through February 2023.
Usage | JCI | PMC |
---|---|---|
Text version | 143 | 0 |
20 | 4 | |
Scanned page | 111 | 2 |
Citation downloads | 9 | 0 |
Totals | 283 | 6 |
Total Views | 289 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.