To determine whether the increased filtration of serum proteins after glomerular injury is the consequence of altered electrostatic properties of the glomerular capillary wall, we measured fractional clearances of the anionic polymer, dextran sulfate, in nine Munich-Wistar rats in the early autologous phase of nephrotoxic serum nephritis (NSN). In agreement with previous studied from this laboratory, whole kidney and single nephron glomerular filtration rates were normal in NSN rats despite histological evidence of glomerular injury, and despite a marked reduction in the glomerular capillary ultrafiltration coefficient to approximately one-third of normal. In the companion study (9), it was shown that in NSN rats the mean fractional clearances of neutral dextrans over the range of effective molecular radii from 18 to 42 A were reduced, compared to normla. In contrast, in the present study the mean fractional clearances for dextran sulfate over the same range of molecular radii were significantly greater than those found previously for normal Munich-Wistar rats. The fractional clearance of dextran sulfate molecules of the same molecular radius as serum albumin (approximately 36 A) was increased markedly, from 0.015 +/- 0.005 (SEM) in nonnephritic controls to 0.24 +/- 0.03 in NSN (P less than 0.001). The sialoprotein content of glomeruli, estimated by the colloidal iron reaction, was reduced in NSN rats as compared to normal controls. It is concluded that the abnormal filtration of anionic serum proteins, such as albumin, seen in glomerulopathies is, at least in part, the consequence of loss of fixed negative charges from the glomerular capillary wall.
C M Bennett, R J Glassock, R L Chang, W M Deen, C R Robertson, B M Brenner, j l Troy, I R ueki, B Rasmussen
Usage data is cumulative from April 2023 through April 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 90 | 0 |
65 | 13 | |
Scanned page | 97 | 1 |
Citation downloads | 16 | 0 |
Totals | 268 | 14 |
Total Views | 282 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.