Direct measurements of portal flow and pressure in a relatively large number of patients with cirrhosis show a marked reduction in flow associated with a nearly constant plateau of portal pressure. This lack of correlation indicates the complex relationships of resistances in the splanchnic, collateral, and hepatic circuits determining the division of the available splanchnic flow between the portal vein and the collateral pathways. Subtracting the measured portal flow from well-established estimates of total hepatic blood flow in cirrhosis suggests that the hepatic artery contributes more than one-half of the blood perfusing the cirrhotic liver. There was no instance of retrograde portal flow during the preshunt measurements, although such reversal was frequent after side-to-side portacaval anastomosis. Attempting to explain the plateau of portal pressure in the face of an increasing outflow resistance presumably associated with progress of the disease, we postulate that an augmented inflow resistance to the splanchnic chamber reduces splanchnic flow in cirrhosis. End-to-side portacaval anastomosis did not return normal portal flow, although it decreased pressure to accepted control levels. The assumption is that most of the splanchnic blood was flowing through the shunt, leading to a high splanchnic resistance in the immediate postshunt status. If this resistance was previously elevated, as suggested by the plateau of portal pressure, the mechanism responsible for the elevation was not immediately deactivated after the shunt, and the true effect of the operation upon splanchnic flow may not be measurable at such time.
Augusto H. Moreno, Albert R. Burchell, Louis M. Rousselot, William F. Panke, S. Frederick Slafsky, Jean H. Burke
Usage data is cumulative from July 2024 through July 2025.
Usage | JCI | PMC |
---|---|---|
Text version | 204 | 33 |
65 | 19 | |
Figure | 0 | 2 |
Scanned page | 480 | 15 |
Citation downloads | 73 | 0 |
Totals | 822 | 69 |
Total Views | 891 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.