To define the factors responsible for the inactivation of the active fragment derived from Factor XII (Factor XIIf ) in plasma, we studied the inactivation kinetics of Factor XIIf in various purified and plasma mixtures. We also analyzed the formation of 125I-Factor XIIf -inhibitor complexes by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). In purified systems, the bimolecular rate constants for the reactions of Factor XIIf with C-1-inhibitor, alpha 2-antiplasmin, and antithrombin III were 18.5, 0.91, and 0.32 X 10(4) M-1 min-1, respectively. Furthermore, SDS-PAGE analysis revealed that 1:1 stoichiometric complexes were formed between 125I-Factor XIIf and each of these three inhibitors. In contrast, kinetic and SDS-PAGE studies indicated that Factor XIIf did not react with alpha 1-antitrypsin or alpha 2-macroglobulin. The inactivation rate constant of Factor XIIf by prekallikrein-deficient plasma was 14.4 X 10(-2) min-1, a value that was essentially identical to the value predicted from the studies in purified systems (15.5 X 10(-2) min-1). This constant was reduced to 1.8 X 10(-2) min-1 when Factor XIIf was inactivated by prekallikrein-deficient plasma that had been immunodepleted (less than 5%) of C-1-inhibitor. In addition, after inactivation in normal plasma, 74% of the active 125I-Factor XIIf was found to form a complex with C-1-inhibitor, whereas 26% of the enzyme formed complexes with alpha 2-antiplasmin and antithrombin III. Furthermore, 42% of the labeled enzyme was still complexed with C-1-inhibitor when 125I-Factor XII was inactivated in hereditary angioedema plasma that contained 32% of functional C-1-inhibitor. This study quantitatively demonstrates the dominant role of C-1-inhibitor in the inactivation of Factor XIIf in the plasma milieu.
A de Agostini, H R Lijnen, R A Pixley, R W Colman, M Schapira
Usage data is cumulative from April 2023 through April 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 142 | 0 |
70 | 18 | |
Scanned page | 113 | 3 |
Citation downloads | 18 | 0 |
Totals | 343 | 21 |
Total Views | 364 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.